| Graphite transfer/circulation
pumps |
 |
|
DT-1501 TRANSFER / CIRCULATION PUMP
ADAPTS TO YOUR NEEDS - CIRCULATE OR TRANSFER IN 1
 |
|
| CHARACTERISTICS |
* Transfer or circulate with the same pump
* Dual output with patented high volume penteller
* Useful for furnaces with a small well
* Pneumatic cylinder powered actuator
* Can be remotely operated
* Pump does not need to be removed to change
functions |
| |
| SPECIFICATIONS |
Flow Rates:
Circulation
Transfer
Transfer Head
Motor Requirements
Minimum Well Size
Metal Level Requirements
Transfer Pipe Size |
1500 lbs/min. @ 1160 rpm
1500 lbs/min. @ 900 rpm
5 ft.
2 HP 3 phase
230/460 VAC 60 Hz
18" x 18"
10" min. - 22" max.
3" |
|
| |
| DIMENSIONS |
Floor to Bottom of Motor Mount
Base Length x Width
Overall Height
Motor Mount Dimensions |
26.5"
12.75" x 13.25"
57"
18" x 18" |
|
|
|
|
|
|
| |
| Improve Melt Rate As Much As 25% |
|
 |
The Junkyard Dog™ BT Dual-Intake circulation pump chews through your
meanest melt more effectively, salvaging more aluminum from every melt while
continually deflecting impurities from the pump well. The Junkyard Dog will:
- Increase melt cycle rates through increased velocity
- Reduce stack temperatures and related energy costs
- Decrease installation time and maintenance requirements
- Reduce inventory parts requirements
- Extend service life
Performance.
Ask us to prove it.
|
|
| Chews Through Your Meanest Melt |
 |
- Dual intake keeps pump well cleaner, reducing energy costs and improving performance.
- Rugged design handles hard particulates suspended in the melt for extended life in demanding production environments.
- Unique compact cartridge is pre-aligned and cemented, for easy installation in less than 15 minutes.
- Stirring action of the intake holes removes impurities from
the pump well forcing them to the top where they can be removed to
reduce jamming.
- Safety Coupling and shear pin protect the shaft and impeller from premature failure, reducing repair and replacement costs.
- Simple design reduces inventory parts requirements while reducing replacement time for a shaft/impeller combo to 5 minutes.
- Proprietary oxidation resistant treatment of submerged components, with 100% penetration greatly extends service life.
- High velocity flow reduces surface oxidation, salvaging more aluminum and increasing melt rate.
|
|
BTS1 Pump
JUNKYARD DOG |
 |
Dimensions and Specifications |
Maximum Flow Rate: 2,000 lbs/min.
Air Drive: 2hp @ 900 rpm -70 p.s.i.
100 s.c.f.m. - 1" supply line
Minimum Well Size: 12" x 20"
Height from base to motor mount: 26.25"
Pump Weight: 150 lbs.
|
| Typical Applications |
Aluminum Recyclers
Scrap Melters
Silicon Alloys
High Volume Furnaces
Dirty Melts
Gas Injection Applications
|
| Patents |
| US |
CANADA |
6,019,576
5,622,481
4,786,230
|
2,235,862
1,264,126
|
| PATENTS PENDING |
|
|
| |
BTS4 Pump
JUNKYARD DOG |
 |
Dimensions and Specifications |
Maximum Flow Rate: 8,000 lbs/min.
Air Drive: 7.5hp @1200 rpm -100 p.s.i.
220 s.c.f.m. - 1" supply line
Minimum Well Size: 21" x 21"
Height from base to motor mount: 40.25"
Pump Weight: 380 lbs.
|
| Typical Applications |
Aluminum Recyclers
Scrap Melters
Silicon Alloys
High Volume Furnaces
Dirty Melts
Gas Injection Applications
|
| Patents |
| US |
CANADA |
6,019,576
5,622,481
4,786,230
|
2,235,862
1,264,126
|
| PATENTS PENDING |
|
|
| |
BTSE8 Pump
JUNKYARD DOG |
 |
Dimensions and Specifications |
Maximum Flow Rate: 16,000 lbs/min.
Electric Drive: 15hp @ 960 rpm, 60 Hz
480V - 3 phase
Minimum Well Size: 26" x 25"
Height from base to motor mount: 40.25"
Pump Weight: 850 lbs.
|
| Typical Applications |
Aluminum Recyclers
Scrap Melters
Silicon Alloys
High Volume Furnaces
Dirty Melts
Gas Injection Applications
|
| Patents |
| US |
CANADA |
6,019,576
5,622,481
4,786,230
|
2,235,862
1,264,126
|
| PATENTS PENDING |
|
|
| |
BTSE15 Pump
JUNKYARD DOG |
 |
Dimensions and Specifications |
Maximum Flow Rate: 30,000 lbs/min.
Electric Drive: 25hp @ 960 rpm, 60 Hz
480V - 3 phase
Minimum Well Size: 30" x 28"
Height from base to motor mount: 43"
Pump Weight: 1200 lbs.
|
| Typical Applications |
Aluminum Recyclers
Scrap Melters
Silicon Alloys
High Volume Furnaces
Dirty Melts
Gas Injection Applications
|
| Patents |
| US |
CANADA |
6,019,576
5,622,481
4,786,230
|
2,235,862
1,264,126
|
| PATENTS PENDING |
|
|
Zinc Transfer & Circulation Pumps |

Pump
Model |
Pump Only
Weight
(lbs.) |
Circulation
Rate
(lbs./min.) |
Transfer
Rate
(lbs./min.) |
Pump Well
Dimensions |
Direct
Electric
Drive |
Air Drive
Requirements
(CFM) |
B501*
B/T1001
B1501
T2001
T2001SD
T4001
T4001SD
CT6001**
B/T6001
B/T6001SD
T120001
T12001SD
T20001SD
B20001SD
T20001
|
75
100
110
150
140
200
200
220
260
260
400
400
450
450
450
|
N/A
N/A
N/A
N/A
2000
N/A
4000
6000
N/A
6000
N/A
12000
20000
40000
N/A
|
500
1000
1500
2000
N/A
4000
N/A
N/A
6000
N/A
12000
N/A
N/A
N/A
20000
|
12"x12"
14"x14"
16"x16"
20"x16"
20"x16"
20"x16"
20"x16"
24"x20"
24"x20"
24"x20"
26"x22"
26"x22"
30"x26"
30"x26"
30"x26"
|
N/A
3HP/1800RPM
5HP/1800RPM
7.5HP/1800RPM
7.5HP/1800RPM
10HP/1200RPM
10HP/1200RPM
15HP/1200RPM
15HP/1200RPM
15HP/1200RPM
25HP/1200RPM
25HP/1200RPM
40HP/1200RPM
50HP/1200RPM
50HP/1200RPM
|
120 @ 90psi
120 @ 90psi
120 @ 90psi
180 @ 90psi
180 @ 90psi
180 @ 90psi
180 @ 90psi
180 @ 90psi
180 @ 90psi
180 @ 90psi
400 @ 90psi
400 @ 90psi
400 @ 90psi
400 @ 90psi
400 @ 90psi
|
* For laboratory usage only
OPTIONS: |
|
- Multi-speed electric control unit
- Digital RPM readout
- Special pump lengths
|
|
| |
|
PREHEAT STATIONS
For Pumps & Degassing Systems
Standard Models
DH-102 |
DH-104 |
DH-106 |
DH-108 |
A800/Z2500
A1500/Z4500
T1001
T1001-SD
H/T800
|
T/H2000/2000SD
T1501 series
T2001 series
T4001 series
T6001 series
|
H/T6000-C
H/T6000-SD
T12001-SD
|
T/H12000 - 3 post SD
T/H12000 - 4 post
T12001-SD
|
The H/T/M6000-CSD & H/T/M12000-CSD will require a special order.
These preheat stations are available for pumps made by other manufacturers.
|
Key selling features are safety, even heating, less down time
between pump changes, and completely dried cement. Other
key features are bulleted below:
- Reduces risk of thermal shock
- Removes moisture
- Decreases preheat time
- Units available for all molten metal pumps
- Custom sizes upon request
- Electric or gas models
- May be used as an assembly oven with minor modifications
Each model has an easily removed door for accessability. |

The "Doghouse" Pump Preheat Station
|
We also offer: |
|
|
| |
*Degassing Systems
*Conversion Kits for 3rd Party Degassing Systems
*Molten Metal Pump Control Systems
*Digital Readout Systems
*Engineering and Design Services |
| |
|
|
|